The Rosemount 5900S Radar Level Gauge delivers ±0.5 mm (0.020 in.) instrument accuracy, reducing level measurement uncertainty to a minimum. It enhances your storage operation by providing certified custody transfer accuracy, better inventory management and reliable loss control data.
The Rosemount 5900S is normally combined with high precision multi-spot temperature sensors for highest accuracy API standard net volume calculations.
The Rosemount 5900S takes overfill safety to a higher level with an innovative 2-in-1 feature which includes two radar gauges in one housing for independent level and overfill measurement. It is SIL 2 and SIL 3 certified according to IEC 61508 and enables API 2350 compliant solutions.

– Product Datasheet  –
 Download
Instrument accuracy ± 0.5 mm (0.020 in.)
Fieldbus (standard) FOUNDATION Fieldbus FISCO (Tankbus)
Repeatability 0.2 mm (0.008 in.)
Measurement principle FMCW-method (Frequency Modulated Continuous Wave)
Output variables and units Level, and ullage: meter, centimeter, millimeter, feet, or inch
  Level rate: meter/second, meter/hour, feet/second, feet/hour, inch/minute
  Signal strength: mV
Power supply FISCO: 9.0 – 17.5 VDC polarity insensitive (for example from Rosemount 2410 Tank Hub)
Ambient operating temperature -40 to +70 °C (-40 to +158 °F). Minimum start-up temperature is -50 °C (-58 °F)
Ingress protection IP 66/67 and Nema 4X
Measuring range 1.2 to 30 m (3.9 to 100 ft) below flange.
Operating temperature in tank Max. +230 °C (+445 °F)
Tank connection 5 in. hole pattern according to ANSI 5 in. Class 150
  5 in. hole pattern according to ANSI 5 in. Class 150
  6 in. hole pattern according to ANSI 6 in. Class 150 / DN 150 PN 16
  8 in. hole pattern according to ANSI 8 in. Class 150 / DN 200 PN 10
  10 in. hole pattern according to ANSI 10 in. Class 150 / DN 250 PN 16
  12 in. hole pattern according to ANSI 12 in. Class 150
   
   
   
   
Rosemount 5900S Radar Level Gauge